| Input Voltage |
90 ~ 264Vac 135 ~ 370Vdc |
| Input Frequency |
47 ~ 63Hz |
| Input Current |
0.31A/115Vac 0.16A/230Vac |
| Inrush Current |
25A/ 115Vac 45A/ 230Vac, cold start |
| Leakage Current |
0.25mA/ 240Vac |
| Set Up, Rise, Hold Up Time |
500ms, 20ms, 30ms/230Vac 500ms, 20ms, 10ms/115Vac at full load |
| Over Load Protection |
>105% rated output power |
|
Hiccup mode, recovers automatically after fault condition is removed |
| Over Voltage Protection |
115% ~ 135% |
|
Clamp by zener diode |
| Over Temperature Protection |
U1 Tj 140°C typically (U1) Detect on main control IC |
|
Shut down o/p voltage, recovers automatically after temperature goes down |
| Working Temperature |
0°C ~ +50°C (Refer to output load derating curve) |
| Working Humidity |
20% ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-20°C ~ +85°C, 10 ~ 95% RH |
| Temperature Coefficient |
±0.03% /°C (0°C ~ 40°C ) |
| Vibration |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
| Withstand Voltage |
I/P-O/P:3KVAC |
| Isolation Resistance |
I/P-O/P:100M Ohms / 500VDC/ 25/°C 70% RH |
| Safety Standards |
UL60950-1, CSA22.2, BSMI CNS14336 approved |
| EMC |
Compliance to FCC part15 class B, EN55022, EN61204-3 class B, BSMI CNS13438; EN61000-3-2,3; |
|
EN61000-4-2,3,4,5,6,8,11, ENV50204, EN61204-3, light industry level, criteria A |
| MTBF |
1414.6Khrs min. MIL-HDBK-217F (25°C ) |
| DC Plug |
Standard type P1I: 2.1x5.5x9.5mm turning fork type, center positive for stock |
|
Other type available by customer request |
| DC Cable |
Standard type UL1185 6ft (4FT only for 5V output) for stock; |
|
Other type available by customer request |