| Ripple & Noise |
75mV |
| Output Voltage Tolerance |
±2.0% max. |
| Line Regulation |
±1.0% |
| Shutdown Idle Current |
20mA / 12Vdc |
| Over Load Protection |
Above 105% rated output power |
|
Over power limiting, recovers automatically after fault condition is removed |
| Short Circuit Protection |
Recovers automatically after fault condition is removed |
| On/Off Control |
Logic 1 OPEN: ON Logic 0 GND: OFF |
| Working Temperature |
-25°C to +70°C |
| Working Humidity |
0% ~ 95% RH Max |
| Storage Temperature, Humidity |
-40°C to +85°C, 0~95%RH |
| Temperature Coefficient |
±0.03%/°C (0~60°C) |
| Isolation Voltage |
I/P-O/P: 1.5KVDC |
| Isolation Resistance |
I/P-O/P: 100M Ohms/500VDC 25°C 70% RH |
| Safety Standards |
Design refers to UL60950-1,TUV EN60950-1 |
| EMC |
Compliance to EN55022 (CISPR22) Class B, EN61000-4-2,3,4,6,8; |
|
EN55024, Light industry level, criteria A |
| MTBF |
2138.2K hrs min. MIL-HDBK-217F (25°C) |