Features
- True sine wave output (THD<3%)
- High surge power up to 2000W
- High efficiency up to 92%
- Power ON-OFF switch
- Standby saving mode can be selected
- Front panel indicator for operation status
- Thermostatically controlled cooling fan
- Battery low alarm, battery low shutdown, over voltage, over temperature, output short, input polarity reverse, over load protections
- Built in cooling fan ON-OFF control
- Optional monitoring software
- Output AC voltage selectable by setting button
- 100 ~ 120VAC Output version available
- Worldwide AC output receptacle options available
TS-1000 is a high performance true sine wave DC/AC power inverter that uses high frequency circuit topology. With high efficiency up to 92% this dc/ac inverter can provide 1000W continuously and peak load of 1150W for 3 minutes, 1500W for 10 seconds or 2000W surge power for 30 utility cycles.
Additional information
Manufacturer | MEAN WELL |
---|---|
Standards | |
Type | DC/AC |
Outputs | Single |
- Home appliances
- power tools
- office equipment
- portable equipment
- vehicles
- yachts
OUTPUT | |
Rated Power | 1000W |
Maximum Output Power | 1150W for 180 sec./1500W for 10 sec./surge power 2000W for 30 cycles |
AC Voltage | 200/220/230/240VAC selectable by setting button |
Frequency | 50±0.1%Hz 50/60Hz selectable by setting button S.W |
Waveform | tRUE SINE WAVE (thd<3%) at rated input voltage |
AC Regulation | ±3.0% |
Saving Mode | Load <5W will be changed to standby mode |
Front Panel Indicator | Battery voltage level, output load level, saving mode, fault and operation status |
*************************** | |
INPUT | See table below for model specifics |
No Load Dissipation | <6W @ standby saving mode |
Off Mode Current Draw | <1mA |
Battery Types | Open & sealed lead acid |
Input Bat. Polarity Protection | By internal fuse open |
*************************** | |
Over Temperature Protection | 65°C ±5°C |
Shut down o/p voltage, re-power on to recover; | |
by internal RTH3 detect on heatsink of power transistor | |
Output Short Protection | Shut down o/p voltage, re-power on to recover |
Over Load Protection | 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. |
Shut down o/p voltage, re-power on to recover | |
GFCI Protection | None |
Working Temperature | 0°C ~ 40°C @ 100% load |
Working Humidity | 20% ~ 90% RH non-condensing |
Storage Temperature, Humidity | -30°C ~ +70°C/-22°F ~ +158°F, 10 ~ 95% RH |
Vibration | 10 ~ 500Hx, 5G 10min./1 cycle, 60 min. each along X, Y, X axes |
Withstand Voltage | Bat I/P-AC O/P:3.0KVAC AC O/P - FG:1.5KVAC |
Isolation Resistance | Bat I/P-AC O/P, Bat I/P-FG:100M Ohms/500VDC |
Safety Standards | EN60950-1 |
EMC | Compliance to EN55022 Class A, 72/245/ CEE, 95/54/ CE, E-Mark, |
EN61000-4-2, 3, 8; ENV50204 |
Part No | Input Bat. Voltage | Input Volt. Range | Input DC Current | Eff. | Fuse Protection | Bat. Low Alarm | Bat. Low Shutdown |
---|---|---|---|---|---|---|---|
TS-1000-212D | 12V | 10.5 ~ 15VDC | 100A | 90% | 40A*2 | 11.3±4% | 10.5±4% |
TS-1000-224D | 24V | 21 ~ 30VDC | 50A | 91% | 40A*2 | 22.5±4% | 21±4% |
TS-1000-248D | 48V | 42 ~ 60VDC | 25A | 92% | 20A*2 | 45±4% | 42±4% |
Products in this Range
Part number | Power (watts) | Voltage (max/rated) | Efficiency (%) | |
---|---|---|---|---|
TS-1000-212D | 1000W | 230VAC | 90% | Request Quote |
TS-1000-224D | 1000W | 230VAC | 91% | Request Quote |
TS-1000-248D | 1000W | 230VAC | 92% | Request Quote |