Sunpower UKSunpower UK
Sunpower UK Product Search

Advanced Search

Featured Product

Request Information

Clipbook

You haven't added any products to your clip book yet.

BS-EN-ISO 9001:2000 certified BS-EN-ISO 9001:2000 certified
We make every effort to ensure the information provided is accurate however we can not be held responsible for errors. Specifications are subject to change without notice; please ensure you conduct testing to ensure the product is suitable for your intended application.

New Products

300W PFC Single Output Battery Charger

300W PFC Single Output Battery Charger Designed for lead acid batteries featuring 3 stage charging characteristics and the automated...
All New Products

In Development

80W Green Mode Single Output AC-DC Desktop Adapter

80W Green Mode Single Output AC-DC Desktop Adapter Designed for both medical and ITE applications SNP-A08 Series features no load input power of <0.3...
All Products in Development

DR-60 Series - 60W Single Output DIN Rail Power Supply

Features

  • Universal AC input/Full range
  • Short circuit/Over Load/Over voltage protection
  • Cooling by free air convection
  • Can be installed on DIN rail TS-35/7.5 or 15
  • UL 508 (industrial control equipment) approved
  • Isolation Class II
  • LED indicator for power on
  • 100% full load burn-in test

Applications

  • Power distribution boxes
  • Control cabinet
  • Building automation
  • Household appliance control

Description

60W single output Class II DIN rail switching power supply for the fast growing demand of the DIN rail segment. With Class II protection levels, this series provides users with a safer operating environment and featuring up to 86% efficiency, this series can be cooled by free air convection to significantly increase the reliability and lifetime of the power supply. Also complies with the safety and EMC requirements of EN50178.

Standards

CBTUVCSUUSCE
DR-60 Series Product Image - DR-60 Series - 60W Single Output DIN Rail Power Supply

Case Details

78 x 93 x 56mm

Specification

Input Voltage 88 ~ 264VAC 124 ~ 370VDC
Input Frequency 47~63Hz
AC Current 1.2A/115VAC 0.8A/230VAC
Inrush Current (max.) 18A/115VAC 36A/230VAC, cold start
Setup, Rise Time 100ms, 30ms/230VAC 200ms, 30ms/115VAC at full load
Hold Time (Typ.) 100ms/230VAC 23ms/115VAC at full load
Over Load Protection 105 ~ 160% rated output power
Constant current limiting, recovers automatically after fault condition is removed
Over Voltage Protection Shut down o/p voltage, re-power on to recover
Working Temperature -20°C to +60°C (Refer to output load derating curve)
Working Humidity 20% to 90% RH non-condensing
Storage Temp., Humidity -40°C to +85°C , 10% to 95% RH
Temp. Coefficient ±0.03%/°C (0°C to 50°C)
Vibration 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Safety Standards UL60950-1, TUV EN60950-1 Approved, Design refer to EN50178
Withstand Voltage I/P-O/P:3KVAC
Isolation Resistance I/P-O/P:100M Ohms/500VDC
EMC Compliance to EN55011,EN55022 (CISPR22) Class B, EN61000-3-2,-3
EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-1, EN61204-3 Light industry, criteria A
MTBF 216.2K hrs min. MIL-HDBK-217F (25°C)
Dimensions 78 x 93 x 56mm

Items

DR-60 Series Output Data

Part No Voltage Rated Current Current Range Rated Power R&N (max) Volt. Adj. Tol. Line Reg. Load Reg. Eff (typ) OVP
DR-60-5 5V 6.5A 0 ~ 6.5A 32.5W 80mV 4.75 ~ 5.5V ±2.0% ±1.0% ±1.0% 76% 5.75 ~ 6.75V
DR-60-12 12V 4.5A 0 ~ 4.5A 54W 120mV 11.1 ~ 13.2V ±1.0% ±1.0% ±1.0% 82% 13.8 ~ 16.2V
DR-60-15 15V 4A 0 ~ 4A 60W 120mV 13.5 ~ 16.5V ±1.0% ±1.0% ±1.0% 83% 17.25 ~ 20.25V
DR-60-24 24V 2.5A 0 ~ 2.5A 60W 150mV 21.6 ~ 26.4V ±1.0% ±1.0% ±1.0% 84% 27.6 ~ 32.4V

DR-60 Series Terminal Pin Assignment

Pin No Assignment Pin No Assignment
1 AC/N 5, 6 -V
2 AC/L 7 LED
3, 4 +V 8 +V Adj.