| Input Voltage Range |
85VAC ~ 264VAC |
| Input Frequency |
47 ~ 63Hz |
| Inrush Current |
50A peak or less (AC 100V), 100A peak or less(AC 240V), rated output & cold start |
| Efficiency |
68% typ (AC100V), 71% typ (AC240V) |
| Power Factor |
98% typ (AC100V), 92% typ (AC240V) |
| Leakage Current |
0.5mA or less (AC100V)/1mA or less (AC240V) |
| Rise Time |
Within 100mS |
| Operating Temperature |
0°C – 50°C : Derating to 60%/50°C |
| Operating Humidity |
10 – 90% RH, No condensating |
| Storage Temperature, Humidity |
-25°C – +70°C, 10 – 95% RH, No condensating |
| Cooling |
Forced air cooling (Temperature sensing typevariable-speed fan motor) |
|
|
|
|
|
|
|
|
| Dielectric Strength |
I/P-FG, O/P-I/P: 1.5kV/minute |
| Insulation Resistance |
AC1500V for one miniute between AC Inputs and DC-outputs/DC-inputs/FG |
| Safety Standards |
UL60950, CSA C22.2 No.60950, EN60950 approved |
| EMC |
Conforms to IEC-61000-4-5; VCCI Class B, FCC Class B, EN55022 Class B |
|
IEC61000-3-2 Class A, EN61000-3-2 Class A |
| MTBF |
105,000 Hrs |
|
|
|
|
| BU-300P-24P |
|
| Rated Input Voltage |
24VDC |
| Over Discharge Voltage |
19V typ (Battery circuit shutdown) |
| Efficiency |
67% typ |
| Charge Voltage |
27.3V typ (Full of charge with temperaturecompensation at 25°C) |
| Charge Current |
0.5±0.2A (Battery voltage at 24V) |